SafeAdvantage AP216600 216kW 600v in NEMA Enclosure
SafeAdvantage is made for safety applications and has Eemax's patent-pending Parabolic Heat Design (PHD).
PHD gives you more performance and the confidence to meet safety standards. Prevent overshoot and low pressure drop with PHD actively controlling energy usage and water temperature.
Get faster water heating, more energy savings, and exact temperature control.
Features
• Field-replaceable lead-free, non-ferrous cartridge-style direct heating element
• Thermo-optical sensor protects against improper commissioning or entrained air
• NSF-61 listed construction materials
• Visual user interface
• Multistage element turn-on
• Active energy management ensures optimal energy application based on real-time system demands
• Field adjustable turn-on flow rate
• High-capacity flow meter
• 150 PSI pressure rating
Common applications
√ Emergency Eye and Face Drench (EFD) shower
√ Emergency Eye (EE) wash
√ Anywhere that tepid (warm, not hot) water is needed
Specifications
36-48kw 480v | Size: 17.42"H x 17.13"W x 10.28"D Weight: 42 lbs. |
54-126kw 480v & 32-81kw 208v |
Size: 17.42"H x 26.17"W x 10.28"D Weight: 68 lbs. |
Rated Pressure | 150 psi |
UL Listing | UL 499 |
Unique Features: | Parabolic Heat Design Optic Heat Sensing Safety |
Standard Temp Setting |
90°F |
Temp Accuracy | +/- 1°F at a steady flow |
Max Flow Rate | Approximately 40GPM |
Phase | Three |
NPT Fitting | 1.25" except for AP036480 and AP048480 which are 0.75" |
SafeAdvantage Model Matrix
Model number |
Application |
Voltage |
Power (kW) |
BTU |
Amps per Phase |
Recommended Wire Size |
Activation |
Temperature Rise in °F (GPM) |
||||||||
3 | 4 | 6 | 7.5 | 20 | 23 | 26 | 30 | 40 | ||||||||
AP032208 N4/N4X | EE | 208v |
32 |
109,189 | 89A | 3 AWG | 1.0 | 73 | 55 | 36 | 29 | 11 | 10 | 8 | 7 | 5 |
AP041208 N4/N4X |
EFD | 208v | 41 | 143,310 | 112A | 2 AWG | 1.0 | 93 | 70 | 47 | 37 | 14 | 12 | 11 | 9 | 7 |
AP054208 N4/N4X |
EFD | 208v | 54 | 184,256 | 150A | 1/0 AWG | 1.5 | 123 | 92 | 61 | 49 | 18 | 16 | 14 | 12 | 9 |
AP064208 N4/N4X |
EFD | 208v | 64 | 218,377 | 178A | 3/0 AWG | 1.5 | 146 | 109 | 73 | 58 | 22 | 19 | 17 | 15 | 11 |
AP081208 N4/N4X |
EFD | 208v | 81 | 276,384 | 225A | 4/0 AWG | 2.5 | 147 | 138 | 92 | 74 | 28 | 24 | 21 | 18 | 14 |
AP036480 N4/N4X | EE | 480v | 36 | 122,837 | 43A | 8 AWG | 1.0 | 82 | 61 | 41 | 33 | 12 | 11 | 9 | 8 | 6 |
AP048480 N4/N4X | EFD | 480v | 48 | 163,783 | 57.6A | 6 AWG | 1.0 | 109 | 82 | 55 | 44 | 16 | 14 | 13 | 11 | 8 |
AP054480 N4/N4X | EFD | 480v | 54 | 184,256 | 65A | 6 AWG | 1.5 | 123 | 92 | 61 | 49 | 18 | 16 | 14 | 12 | 9 |
AP072480 N4/N4X | EFD | 480v | 72 | 245,674 | 87A | 3 AWG | 2.5 | 147 | 123 | 82 | 66 | 25 | 21 | 19 | 16 | 12 |
AP096480 N4/N4X | EFD | 480v | 96 | 327,552 | 116A | 1/0 AWG | 2.5 | 147 | 147 | 131 | 109 | 33 | 29 | 25 | 22 | 16 |
AP108480 N4/N4X | EFD | 480v | 108 | 368,511 | 130A | 1 AWG | 2.5 | 147 | 147 | 123 | 98 | 37 | 32 | 28 | 25 | 18 |
AP126480 N4/N4X | EFD | 480v | 126 | 429,930 | 151A | 2/0 AWG | 2.5 | 147 | 147 | 143 | 115 | 43 | 37 | 33 | 29 | 21 |
AP144480 N4/N4X | EFD |
480v | 144 | 491,348 | 173A | 2/0 AWG | 2.5 | 147 | 147 | 147 | 131 | 49 | 43 | 38 | 33 | 24 |
AP216480 N4/N4X | EFD | 480v | 216 | 737,022 | 260A |
300 MCM |
2.5 | 147 |
147 |
147 |
147 |
74 |
64 |
57 |
49 |
37 |
AP108600 N4/N4X | EFD | 600v | 108 | 368,511 | 104A | 2 AWG | 2.5 | 147 | 147 | 123 | 98 | 37 | 32 | 28 | 25 | 18 |
AP162600 N4/N4X | EFD | 600v | 162 | 552,767 | 156A | 2/0 AWG | 2.5 | 147 | 147 | 147 | 147 | 55 | 48 | 43 | 37 | 27 |
AP216600 N4/N4X | EFD | 600v | 216 | 737,022 | 207A | 4/0 AWG |
2.5 | 147 | 147 | 147 | 147 | 74 | 64 | 57 | 49 | 37 |
Suffix Definition
EFD: Emergency Eye and Face Drench Shower
• Ships with maximum temperature setting of 90°F. Apply software update to change temperature.
• Minimum heating element activation temp is 2.5 GPM
• Interface is locked by default
EE: Emergency Eyewash
• Ships with maximum temperature setting of 90°F
• Interface is locked by default
N: NEMA 4
• Standard configuration for the SafeAdvantage. Includes NEMA 4 cabinet. NEMA 4 is the spec for being waterproof
N4X: NEMA 4X
• Includes NEMA 4X 304 stainless steel cabinet. 4X is the spec for being waterproof and corrosion-proof.
Other Optional Features
• NEMA N4X6 (spec for submersion) with 316 stainless steel enclosure
• Leak detection
• Indoor disconnect switch
• Alarm contacts
• Beacon
• Siren
• Stand Kit for freestanding installations
• Explosion Proof (Class 1 Div 1 & 2)
• Freeze Protection
• Additional options are available with custom order
Document Downloads
Troubleshooting
Warranty
Order Submittal Sheet (required with every SpecAdvantage/SafeAdvantage order)
Videos