Eemax SpecAdvantage AP041208 41kW 208v
Patent-pending Parabolic Heat Design (PHD) creates higher performance
SpecAdvantage gives you faster water heating to the set temperature, less wasted energy, and precise temperature control.
Perfect for commercial and industrial applications such as:
≈ Process Hot Water
≈ Heavy and light industrial such as manufacturing processes, oil/gas/chemical, and power plants
≈ Commercial Kitchens
≈ Sanitation and dishwasher booster
≈ Drench Showers
≈ Eye Wash Stations
≈ Eye/Face Showers
≈ Waste water treatment plants
Features
• Field replaceable lead-free, non-ferrous cartridge-style direct heating element
• Thermo-Optical sensor protects against improper commissioning or entrained air
• NSF-61 listed construction materials
• Visual user interface
• Elements activate in multiple stages
• Active energy management ensures optimal energy application based on real-time system demands
• Field adjustable turn-on flow rate
• High-capacity flow meter
• 150 PSI pressure rating
Specifications
36-48kw 480v | Size: 17.42"H x 17.13"W x 10.28"D Weight: 42 lbs. |
54-126kw 480v & 32-81kw 208v |
Size: 17.42"H x 26.17"W x 10.28"D Weight: 68 lbs. |
Rated Pressure | 150psi |
UL Listing | UL 499 |
Unique Features | Parabolic Heat Design Optic Heat Sensing Safety |
Standard Temp Setting |
120°F (Adjustable from 80 to 140°F) |
Temp Accuracy | +/- 1° at a steady flow rate |
Max Flow Rate | Approximately 40gpm |
Phase | Three |
NPT Fitting | 1.25" |
SpecAdvantage Model Matrix
36-48kw 480v | Size: 17.42"H x 17.13"W x 10.28"D Weight: 42 lbs. |
54-126kw 480v & 32-81kw 208v |
Size: 17.42"H x 26.17"W x 10.28"D Weight: 68 lbs. |
Rated Pressure | 150 psi |
UL Listing | UL 499 |
Unique Features | Parabolic Heat Design Optic Heat Sensing Safety |
Standard Temp Setting |
120°F (Adjustable from 80 to 140°F) |
Temp Accuracy | +/- 1°F at a steady flow rate |
Max Flow Rate | Approximately 40 GPM |
Phase | Three |
NPT Fitting | 1.25" |
SpecAdvantage Model Matrix
Model number |
Available Options |
Voltage |
Power (kW) |
BTU |
Amps per Phase |
Recommended Wire Size |
Activation |
Temperature Rise in °F (GPM) | ||||||||
3 | 4 | 5 | 6 | 20 | 23 | 26 | 30 | 40 | ||||||||
AP032208 | EE, S | 208v | 32 | 109,189 | 89A | 1 AWG | 1.0 | 73 | 55 | 36 | 29 | 11 | 10 | 8 | 7 | 5 |
AP036208 | EE, S | 208v | 36 | 122,832 | 100A | 1 AWG | 1.0 | 82 | 61 | 49 | 41 | 12 | 11 | 9 | 8 | 6 |
AP041208 | EFD, S | 208v | 41 | 143,310 | 112A | 1 AWG | 1.0 | 93 | 70 | 47 | 37 | 14 | 12 | 11 | 9 | 7 |
AP054208 | EFD, S | 208v | 54 | 184,256 | 150A | 2/0 AWG | 1.5 | 123 | 92 | 61 | 49 | 18 | 16 | 14 | 12 | 9 |
AP064208 | EFD, S | 208v | 64 | 218,377 | 178A | 3/0 AWG | 2.5 | 146 | 109 | 73 | 58 | 22 | 19 | 17 | 15 | 11 |
AP036480 | EE, S | 480v | 36 | 122,837 | 43A | 8 AWG | 1.0 | 82 | 61 | 41 | 33 | 12 | 11 | 9 | 8 | 6 |
AP039480 | EE, S | 480v | 39 | 133,068 | 47A | 6 AWG | 1.0 | 89 | 67 | 53 | 44 | 13 | 12 | 10 | 9 | 7 |
AP048480 | EFD | 480v | 48 | 163,783 | 58A | 6 AWG | 1.0 | 109 | 82 | 55 | 44 | 16 | 14 | 13 | 11 | 8 |
AP054480 | EFD | 480v | 54 | 184,256 | 65A | 4 AWG | 1.5 | 123 | 92 | 61 | 49 | 18 | 16 | 14 | 12 | 9 |
AP063480 | EFD, S | 480v | 63 | 214,956 | 76A | 3 AWG | 2.5 | 143 | 108 | 86 | 72 | 22 | 19 | 17 | 14 | 11 |
AP072480 | EFD | 480v | 72 | 245,674 | 87A | 3 AWG | 2.5 | p | 123 | 82 | 66 | 25 | 21 | 19 | 16 | 12 |
AP096480 | EFD, S | 480v | 96 | 327,552 | 116A | 1/0 AWG | 2.5 | p | p | 131 | 109 | 33 | 29 | 25 | 22 | 16 |
AP108480 | EFD | 480v | 108 | 368,511 | 130A | 1/0 AWG | 2.5 | p | p | 123 | 98 | 37 | 32 | 28 | 25 | 18 |
AP126480 | EFD | 480v | 126 | 429,930 | 151A | 2/0 AWG | 2.5 | p | p | 143 | 115 | 43 | 37 | 33 | 29 | 22 |
AP144480 | EFD | 480v | 144 | 491,348 | 173A | 3/0 AWG | 2.5 | p | p | p | p | 49 | 43 | 38 | 33 | 25 |
AP216480 | EFD | 480v | 216 | 737,022 | 260A | 300 MCM | 2.5 | p | p | p | p | 74 | 64 | 57 | 49 | 36 |
AP130600 | EFD | 600v | 130 | 443,578 | 125A | 1 AWG | 2.5 | p | p | p | 118 | 44 | 39 | 34 | 26 | 22 |
AP150600 | EFD | 600v | 150 | 511,821 | 144A | 1/0 AWG | 2.5 | p | p | p | p | 51 | 45 | 39 | 24 | 16 |
"p" in the table above indicates that the temperature is electronically limited to a maximum, factory-preset, temperature.
Suffix Definitions
EFD: Emergency Eye and Face Drench Shower
• Ships with maximum temperature setting of 90°F. Apply software update to change temperature.
• Minimum heating element activation temp is 2.5 GPM
• Interface is locked by default
EE: Emergency Eyewash
• Ships with maximum temperature setting of 90°F
• Interface is locked by default
S: Sanitation
• Ships with a temp setting of 180°F with possible setting range of 100° to 190°F
Other Optional Features
• NEMA N4, N4X (304SS) N4X6 (316SS) enclosures with the SafeAdvantage heaters
NEMA is a spec for waterproof and corrosion-proof enclosures
• Freeze protection for harsh environments, down to -30°F
• Explosion-proof enclosure
• Electrical disconnect
• GFCI
Document Downloads
Troubleshooting
Warranty
Order Submittal Sheet (required with every SpecAdvantage/SafeAdvantage order). SpecAdvantage and SafeAdvantage heaters are custom made three phase units on order and cannot be returned.
Videos